Temperature Fuse
250v 2a /10a Thermal cut link for Table fan/ Blender
Thermal fuse can sense the overheating generated by abnormal operation of electrical and electronic products, thereby cutting off the circuit to avoid fire. Commonly used in: hair dryers, electric irons, rice cookers, electric stoves, transformers, motors, water dispensers, coffee pots, etc. The thermal fuse cannot be used again after operation, and only operates once at the melting temperature.
AUPO BF 10A~16A 250V / 125V Metal Thermal Cutoff Fuse
AUPO BF series Thermal Cutoff Fuse products meet the safety test requirements of IEC60691Ed4.0 and GB/T9816.2013, and many models have obtained UL, VDE, CCC, PSE, KC and other safety certifications.
Custom Built in Thermal Fuse link and cable
The thermal fuse is a thermal protector. Thermal fuses are mainly composed of melts and tubes, plus external fillers. When using, connect the thermal fuse in series with the protected circuit. When the current of the protected circuit exceeds the specified value, and after a certain period of time, the melt generated by the melt itself fuses the melt, breaking the circuit, thereby protecting the circuit. Electrical appliances that use a metal conductor as a melt to break a circuit are connected in series in the circuit.
Emerson G4 / G5 series microtemp 10A / 20A thermal fuse
Emerson Group production MICROTEMP® G4 G5 series thermal fuse, According to different product specifications, Rated load current, respectively, up to AC250V 10A, AC120V 15A and DC24V 5A. To provide reliable protection against overheating, In the same industry products, MICROTEMP® G4 G5 series thermal fuse has established its flagship status can not be shaken.
LEAO, DYE, Panasonic, SWC Limiter thermal fuse
The melt material used in LEAO, DYE, Panasonic, SWC thermal fuses plays a vital role in the performance of thermal fuses and is one of the core components of the entire device. According to the characteristics of the melt material, we can divide them into two categories: low melting point and high melting point.
Mechanical resistance thermal cutoffs Devices (DF SF Series 10amp)
Subsequently, the voltage between the contacts of the thermal cutoff and the DC circuit rises to ensure that the DC circuit is disconnected. Through the present invention, the problem that the thermal cutoff in the DC circuit cannot effectively cut off the circuit is solved, and the effect of improving the circuit safety is achieved.
Metal Thermal Fuse for Limit Temperature Protection
Metal thermal fuse link (thermal cut off ) consists of a sliding contact, a spring, and an electrically nonconductive thermal pellet. Before the limit thermal fuse is activated, current flows from the left lead to the sliding contact and through the metal housing to the right lead. Metal Shell Thermal Fuse Cutoff 250VAC 10A Temperature Fuse link TF 72-250℃ (192℃).
Models and Applications of Thermal Cut-Out link Fuse
A thermal fuse is also known as a tmperature fuse, thermal link, thermal cut-out (TCO), or one shot. It is a temperature sensing circuit cut-off device (China custom metal, ceramic, square shell thermal fuse). A limitor thermal fuse can sense the overheating generated by abnormal operation of electrical and electronic products, thereby cutting off the circuit to avoid fire.
Motor of Aupo Axial Thermal Cutoff
rf 250v 10a, 250v / 20A 216 Celsius Circuit Cut-off Temperature Thermal Fuse Ceramics AUPO, RY, RH, DYE, SEFUSE, SET, Emerson, NEC
SET Square TCO Thermal Fuse use Flat iron
A piece of fusible alloy wire is connected between the two pins of the thermal fuse, which is covered by a special transparent resin square shell. Current can flow from one pin to another. When the temperature around the thermal fuse rises to its set operating temperature, its fusible alloy wire melts and shrinks into a spherical shape, and is attached to the ends of the two pins with the help of surface tension and special resin. In this way, the circuit is permanently cut off.
Set square Thermal Limit Cutoffs Fuse use for Coffee maker
SET / AUPO / RY / Uchibashi The thermal fuse is a thermal protection device designed for electronic equipment to provide overheating protection. It adopts a tubular structure, and the spiral melt material is an alloy, which has the characteristics of fast melting. The model of this fuse is BF216, which is small in size and suitable for a variety of electronic equipment.
Tamura/NEC SF metal casing 15A Temperature fuse
The working principle of the AUPO / Tamura / NEC SF thermal fuse is based on the thermal expansion and conductive properties of the material. When the temperature in the circuit rises to the rated trigger temperature of the fuse, the metal material of the fuse will expand due to heat. When this expansion reaches a certain degree, it will cause the resistance inside the fuse to rise sharply.
The Difference Between Thermal Fuse Link and Thermal Cutoff Switch
A “thermal fuse link (Fusible alloy wire and Organic thermal fuse )” is essentially a one-time fusible cut off, heat-sensitive component that permanently breaks a circuit when it reaches a specific temperature. while a “thermal cutoff switch” is a bimetallic strip device that can potentially cut off itself after reaching a high temperature, allowing the circuit to reconnect once the temperature drops below a set point.
Therm-O-Disc microtemp fuse G5 for Refrigerator / Coffee maker
“Therm-O-Disc” thermal disc manufactured G5 series MICROTEMP® thermal fuse, specially designed for high current loads, depending on product specifications, contact capacity were up to AC250V 16A, AC250V 20A and AC120V 25A, entirely through the agency approvals UL and CSA.
thermal fuse and circuit breaker cutoff temperature
They are the same in that they can achieve short circuit protection. The principle of a thermal fuse is to use a current flowing through a conductor to cause the conductor to heat up. When the melting point of the conductor is reached, the conductor is melted so that the circuit-protected electrical appliances and lines are not burned.
Thermal Fuse Function and Application
The Thermal Fuse (Thermal Cutoff, Temperature Fuse) is Axial / Radial / Organic Thermal-Link(OTCO) safety parts that stops the flow of electricity to the motor circuit when a overheats. If the fuse is missing or broken, your motor will not start. The thermal fuse is sensitive to external temperature, and the operating temperature is accurate and stable. Small size, sealed structure. Reliable performance. Low resistance value. One-time action cuts off the current, and the current interruption capacity reaches 250VAC/25A.