Produktkategorien
- Thermosicherung 32
- oberflächenmontierte Sicherungen 12
- Thermistor 36
- Sicherungshalter für Leiterplattenmontage 27
- Kabelbaum 6
- Flachsicherungshalter 17
- Thermostat 50
- Elektro-Sicherung 24
- Kfz -Temperatursensor 7
- Thermischer Schutzschalter 22
- Sicherungskastenhalter 36
- Temperatursensor 75
- Thermischer schalter 68
- Autosicherung 20
- Sicherungen festschrauben 8
Produkt Tags
PTC Thermistor for Air Heating
PTC Thermostatic Heater for Internal Insulation of Instrument and Equipment Chassis in Low-Temperature Environments
Usage Precautions
Use a hair dryer to remove heat to increase heating power. Wind speed significantly affects heating power. Allgemein gesprochen, the higher the wind speed, the greater the power. Without wind, the heater will not be damaged, but the power will drop significantly.
1) The power aging rate is within 10% after 1000 Std., and the resistance aging rate is within 50%.
2) Can be manufactured to customer specifications.
3) Available in both insulated and non-insulated configurations.
PTC Thermostatic Heater for Control Cabinet Dehumidification and Moisture Prevention
Suitable for heating and moisture prevention in electrical control cabinets, dehumidifying and moisture prevention in drying ovens, dehumidifiers, electric humidifiers, moisture prevention and heating for electrical instruments, monitors, Elektroöfen, medizinische Ausrüstung, Haushaltsgeräte, small appliances, und mehr.
Technische Parameter
Modell | L/mm | W/mm | T/mm | Nennspannung (V) | Surge Current (A) | Leistung (W) (5 m/s wind speed) |
MZ9Q-L72W22T15V220W270 | 72 | 22 | 15 | 220 | < 3 | 270 |
MZ9Q-L96W44T15V220W800 | 96 | 44 | 15 | 220 | < 7 | 800 |
MZ9Q-L120W44T15V220W1000 | 120 | 44 | 15 | 220 | < 8 | 1000 |
MZ9Q-L96W66T15V220W1200 | 96 | 66 | 15 | 220 | < 10 | 1200 |
MZ9Q-L96W88T15V220W1500 | 96 | 88 | 15 | 220 | < 11 | 1500 |
MZ9Q-L240W44T15V220W2000 | 240 | 44 | 15 | 220 | < 16 | 2000 |
MZ9Q-L96W44T15V110W800 | 96 | 44 | 15 | 110 | < 14 | 800 |
MZ9Q-L120W44T15V110W1000 | 120 | 44 | 15 | 110 | < 15 | 1000 |
MZ9Q-L96W66T15V110W1200 | 96 | 66 | 15 | 110 | < 18 | 1200 |
MZ9Q-L96W88T15V110W1500 | 96 | 88 | 15 | 110 | < 20 | 1500 |
MZ9Q-L240W44T15V110W2000 | 240 | 44 | 15 | 110 | < 25 | 2000 |
MZ9Q-L48W44T15V24W400 | 48 | 44 | 15 | 24 | 250 | 400 |
MZ9Q-L96W44T15V24W800 | 96 | 44 | 15 | 24 | 250 | 800 |
MZ9Q-L120W44T15V24W1000 | 120 | 44 | 15 | 24 | 250 | 1000 |
Operating Voltage: DC/AC 12V, 24V and DC/AC 110V, 220V
Curie Temperature: 85°C to 220°C
Surface Temperature: 60°C to 190°C
Minimum Dimensions: 60×60×34mm
Maximum Dimensions: 155×85×24mm
Nennleistung: 30–200W
PTC Thermostatic Heater for Internal Insulation of Instrument and Equipment Chassis in Low-Temperature Environments
Suitable for maintaining a constant temperature in the chassis of equipment such as ticket machines, subway gates, and ATMs, preventing malfunctions of electronic components caused by low ambient temperatures.
Technische Parameter
Modell | Nennspannung (V) | Leistung (W) | Abmessungen (mm) | Minimum Temperature Limit (°C) | Upper Temperature Limit (°C) |
MZ9Q-96A2 | 110/220 | 250~400 | 135*120*42 | 3~5 ±3 | 24~28 ±5 |
MZ9Q-96A3 | 110/220 | 600 | 142*125*80 | 5~8 ±5 | 24~28 ±5 |
MA9Q-86A3 | 110/220 | 800 | 200*112*80 | 5~8 ±5 | 24~28 ±5 |
Kontaktiere uns
Warten auf Ihre E-Mail, Wir werden Ihnen innerhalb von 24 Stunden antworten 12 Stunden mit wertvollen Informationen, die Sie brauchten.