我. Core type and functional positioning

Sensor type‌ Installation location Core function Typical resistance (25℃)
Indoor ambient temperature sensor Indoor unit air inlet Monitor room temperature, control compressor start/stop/frequency conversion operation 5KΩ/10KΩ/15KΩ
‌Indoor pipe temperature sensor‌ Evaporator copper tube surface Refrigeration anti-freezing, heating anti-cold wind, control indoor unit wind speed Same ambient temperature or higher
室外環境溫度傳感器 Back of outdoor unit condenser Monitor ambient temperature, adjust outdoor unit fan speed 10KΩ~50KΩ
‌Compressor exhaust temperature sensor Exhaust pipe metal surface Monitor exhaust temperature (>150℃), prevent overheating protection 50KΩ/100KΩ
Outdoor pipe temperature sensor Condenser coil Defrost control and overheating protection 10KΩ~50KΩ

筆記:
Household air conditioners are mainly based on NTC thermistors (temperature↑resistance↓);
The resistance of different sensors of the same air conditioner may be different (such as Panasonic inner ring temperature is usually 15KΩ, tube temperature is 25KΩ).

二. Key performance parameters and selection
‌精度要求‌‌
Ambient temperature sensor: ±0.5℃ (±0.1℃ for high-precision models);
管道溫度傳感器: ±1℃ (key for anti-freeze protection).

‌Temperature range‌
Conventional environment: -30℃~+80℃ (epoxy resin encapsulation);
High temperature area: exhaust gas sensor needs to withstand 150℃↑ (glass seal/gold electrode encapsulation).
‌‌
B value selection‌
Standard B value: 3435K/3950K, affecting the slope of the temperature-resistance curve;
High B value (4100K) improves the sensitivity in the high temperature zone.

三、. Typical faults and diagnostic logic
mermaid Copy Code
graph LR
A[Air conditioning abnormal protection] –> 乙[Check sensor resistance]
乙 –> C{Measured resistance at 25℃}
C — Deviation from nominal value ±3%↑ –> D[Replace sensor]:ml-citation{ref=”11″ data=citationList”}
C — Normal –> 乙[Check the connection line]
乙 — Open circuit/short circuit –> F[Maintenance harness]:ml-citation{ref=”8″ data=citationList”}
乙 — Normal –> G[Mainboard ADC failure]:ml-citation{ref=”9″ data=citationList”}

‌Case‌: Haier air conditioner internal unit pipe temperature sensor nominal 10KΩ, if the actual measurement <9.7KΩ or >10.3千瓦, 它需要更換.

四號. Installation and maintenance specifications
‌Positioning criteria‌
The ambient temperature sensor needs to be exposed to the air flow and avoid local heat sources;
The pipe temperature sensor must fit tightly to the copper tube (filled with thermal conductive silicone grease).
‌Replacement steps‌
Turn off power → remove the control board → unplug the plug → replace the new sensor → restore the test;
It is strictly forbidden to bend the lead (which may cause internal fracture).

V. Technology Evolution Direction
‌Multi-sensor Fusion‌: The new air conditioner uses 4-6 sensors to link and realize dynamic temperature control through spatial temperature field modeling;
‌Intelligent Calibration‌: Automatically detect sensor resistance drift when powered on, and software compensation improves long-term stability.

‌Appendix: Resistance Quick Comparison Table‌

溫度 5K sensor 10K sensor‌
0℃ 16.3千瓦 32.6千瓦
25℃ 5千瓦 10千瓦
50℃ 1.8千瓦 3.6千瓦