China custom bimetallic thermal disc cutoff switch has surface mount and PCB plug-in installation. Overheat circuit cutoffs switch (bimetal thermostat) jsou zařízení navržená tak, aby udržovala komponenty v bezpečí v situacích, kdy dojde k nadměrné teplotě. List of Select Surface Mount Thermal Switches and thermal protectors product Specs, datasheets, manufacturers & suppliers.
Surface Mount Bimetal disc Thermal Switch are indispensable components in the safe and efficient operation of motors/ Electrical appliances. Zabráněním přehřátí, they protect Electrical appliancesfrom damage, prodloužit jejich operační život, Snižte riziko nebezpečí požáru, Zajistěte bezpečný provoz, a minimalizovat náklady na prostoje a údržbu. Navíc, Bimetal disc thermal switch help in complying with industry safety standards, Poskytování klidu mysli operátorům a zúčastněným stranám. Jak technologie postupuje, thermal switch continue to evolve, nabízí přesnější a spolehlivější ochranu motorů v široké škále aplikací.
S vývojem technologie, Rozsah aplikací motoru je stále rozsáhlejší, Zejména použití motoru v každodenním životě a výrobě je také stále důležitější. Ale dochází k nehodě popálení motoru, v reálném životě, Popálení motoru je způsobeno hlavně následujícími blokovanými přehřátími cívky, Zátěž je příliš velké přetížení motoru, Nedostatek fáze a dalších důvodů. Installing a heat protector is one of the effective ways to protect the motor. Tepelný spínač, Také se nazývá spínač teploty, Přepínač regulace teploty, atd. Je to druh teplotního spínače s bimetálním listem jako prvkem snímání teploty, Když elektrické zařízení normálně pracuje, Bimetální list je ve volném stavu, kontakt je v odpojeném stavu, Když teplota stoupá na hodnotu teploty akční, Bimetální prvek je zahříván, aby se vytvořil vnitřní napětí a rychlý účinek, Otevřete kontakt, Odřízněte/připojte obvod, so as to play a bimetal thermal switch role. Wait until the ambient temperature drops to thereset temperature of the protector, Kontakt znovu uzavře připojený obvod, A motor bude znovu fungovat.
Choosing The Right thermal switch
How to choose the right circuit Off bimetal disc switch is very important, Jinak nejen nemůže hrát ochrannou roli, ale způsobí, že motor nemůže fungovat kvůli nesprávnému výběru, nebo dokonce hoří.
1. Napětí & Aktuální stanovení
• Bimetal disc thermal switch have different voltage ranges 400V 380V 230V 220V 110V, DC motors will also have 36V 24V 12V, atd., according to different working voltages to choose different rated voltage protectors, v zásadě, Skutečné aplikační napětí je menší nebo stejné jako jmenovité napětí ochránce, například, 380V motor cannot choose rated voltage 220V protector, a jmenovité napětí 220V Protector lze použít v motoru 110 V;
• The current of the electrical appliances motors is divided into three kinds of starting current, normální pracovní proud a blokovaný proud, the rated current of the protector should be greater than the maximum value of the three currents, a musí opustit marži. Například, Motor normální pracovní proud 1A, Počáteční proud 1.5a, Blokování proudu 2a, then the rated current of the selected protector is at least 2A, A je nejlepší si vybrat jmenovitý proud 3A nebo 5A, aby si udržel okraj. Some motor starting current is greater than the rated current of the protector, Ale počáteční čas je kratší, a normální pracovní proud a blokovací proud jsou menší než jmenovitý proud ochránce, v tomto případě, Můžete si také vybrat tento ochránce. Protože počáteční proud je větší než jmenovitý proud, Ale kvůli krátké době, the thermal effect of the current has not had time to make the double piece heat leading to protection of the protector, Takže to nezpůsobuje misection.
2. Choose to thermal switch the temperature
• The choice of thermal switch temperature is related to three factors: insulation level of enameled wire, installation position and protector type.
The thermal switch temperature is lower than the maximum allowable temperature, například, the maximum temperature ofF class is 155℃, and the actual selection can be 145℃ or 150℃.
•The installation position is divided into built-in inside the coil and bundled outside the coil, because when the motor is blocked and forwarded heat, the overheating phenomenon spreads from inside and outside. If the protector is buried in the interior, the thermal switch temperature is slightly lower than the highest temperature of the enamelled wire; If it is tied outside the coil, consider the temperature difference between the inside and outside, and choose a lower temperature protector. Například, the insulation level is F class enameled wire, coil inside and outside the temperature difference of 20℃, then choose 155-20=135℃ or so of the protector;
Motor protector has protection functions such as overload, selhání fáze, imbalance, underload, grounding/leakage, a stánek. It can form a motor control protection unit with electrical components such as contactors and motor starters. It has functions such as remote automatic control, on-site direct control, panel indication, signal alarm, and field bus communication.
3. Selection of the thermal switch life
Different motor lock-in test time different requirements for the life of the protector are not the same, such as normal household motor lock-in 18 days, the number of cycles of normal action reset will not exceed 100000 časy, the rated voltage current life of more than 100000 times can be selected protector; Some pump motors only do 3 days of blocking, v zásadě, the life requirement is hundreds of times.
4. Selection of the thermal switch for sealing performance
Motor coil in the thermal switch process will dip paint to enhance the insulation performance of the process, dip paint is divided into drop paint, immersion, vacuum into the paint and other processes, especially the vacuum into the paint pressure is large, insulating paint is easy to enter the inside of the protector, resulting in the failure of the protector. The ST01 series of An Electronics has a very high sealing, under the condition of -0.08MP, the paint dipping rate can reach 3%; In the case of -0.03MP, the paint rate can reach less than one in ten thousand.
Motor protector parameters
Technical parameters
Auxiliary power supply |
Technical indicators | |||
ARD2(L) | ARD2F | ARD3 | ||
Auxiliary power supply | Napětí | AC85V~265V/DC100V~350V | ||
Napětí | ≤7VA | ≤15VA | ||
Rated working voltage | AC380V/AC660V,50Hz/60Hz | |||
Rated operating current | 1A(0.1~9999) | |||
5A(0.1~9999) | ||||
1.6A(0.4A~1.6A) | ||||
6.3A(1.6A~6.3A) | ||||
25A(6.3A~25A) | ||||
100A(25A~100A) | ||||
250A(63A~250A) | ||||
800A(250A~800A) | ||||
Relay output contact capacity | AC250V/ 3A;DC30V/ 3A | AC250V/ 6A | ||
Switch input | 2-way | 9-way | ||
Environment | Working temperature: -10°C~55°C | |||
Teplota skladování: -20°C~65°C | ||||
Relative humidity: 5﹪~95﹪ without condensation | ||||
Altitude: ≤ 2000m | ||||
Pollution level | 2 | |||
Úroveň ochrany | IP20 | Main unit IP20 Display unit IP45 | ||
Installation category | Level III |
Bimetal motor protector
Technical parameters | Technical indicators | ||
ARD3T auxiliary power supply | AC/DC 110 / 220V or AC 380V,power consumption≤15VA | ||
Motor rated working voltage | AC 380V / 660PROTI,50Hz / 60Hz | ||
Motor rated working current | 1.6(0.40A-2.00A) | Measured using measurement module | |
6.3(1.6A-6.3A) | |||
25(6.3A-25A) | |||
100(25A-100A) | |||
250(63A-250A) | Using external current transformer + measurement module | ||
800(250A-800A) | |||
Leakage current | 50mA-1A | Using measurement module + leakage current transformer | |
3A-30A | |||
Relay output contact capacity | Resistive load | AC250V、6A;DC24V、6A | |
Inductive load | AC250V、2A;DC24V、2A | ||
Main switch input and output | 4DI、4DO,DI Can be dry or wet node | ||
Switch module | 4DI、3DO,DI Can be dry or wet node | ||
Temperature module | External sensor type:PT100、PT1000、Cu50、PTC、NTC
Number of sensor channels: 3 Corresponding measurement range of sensor: PT100/PT1000:-50°C~+500°C Cu50:-50°C~+150°C PTC/NTC:100Ω~30kΩ |
||
Analog module | Can be realized: 2-way 4~20mA input measurement, 2-way 4~20mA transmission output
4~20mA input measurement accuracy ±0.5% 4~20mA output maximum load capacity is ≤500Ω |
||
Main communication | RS485:Modbus-RTU | ||
Communication module | RS485:Dual Modbus-RTU、Profibus | ||
Environment | Working temperature | -10ºC~55ºC | |
Teplota skladování | -25ºC~65ºC | ||
Relative humidity | ≤95﹪No condensation, no corrosive gas | ||
Altitude | ≤2000m | ||
Pollution level | Level 3 | ||
Úroveň ochrany | Main body IP20, split display module IP45 (installed on the cabinet) | ||
Installation category | Level III | ||