Categories de productes
- fusible tèrmic 32
- Fustes de muntatge superficial 12
- termistor 36
- Suport de fusibles de muntatge de PCB 27
- Arnès de cablejat 6
- Titulars de fusibles de fulla 17
- termòstat 50
- Fusible elèctric 24
- Sensor de temperatura de l’automoció 7
- Interruptor de circuit tèrmic 22
- Fuse Box-titure 36
- Sensor de temperatura 75
- Interruptor tèrmic 68
- Fusible del cotxe 20
- Fustes de forrellat 8
Etiquetes de producte
Replacement Hi-limit Cut off Thermostat & Resettable Thermal Switch
KSD301, KD302, KSD306, KD308 Hi-limit Cut off Thermostat & Resettable Thermal Switch When the circuit is working properly, the contacts are in a closed state. When the rated operating temperature is reached, the bimetal is deformed by heat and breaks quickly, cutting off the circuit. After that, the device begins to cool down.
Hi-limit Cut off Thermostat & Resettable Thermal Switch When the circuit is working properly, the contacts are in a closed state. When the rated operating temperature is reached, the bimetal is deformed by heat and breaks quickly, cutting off the circuit. After that, the device begins to cool down. When it reaches the specified reset temperature, the bimetallic strip and spring strip snap back to their starting position, the contacts will close again, and the device will start working again.
Replacement Resettable Thermal Cutoff Switch process:
Multi-mount Manual Reset High Temp Limit Safety Switch L350°f For heater.
The fuse on the heater is a safety device. The hi-limit thermostat should control the temperature so that the fuse does not blow. Therefore if the fuse does blow the hi-limit thermostat is not regulating the temperature so it is assumed that it is toast. Note that the hi-limit thermostat is also just a safety device.
If the unit is running on the hi-limit thermostat, this indicates a problem as the hi-limit thermostat should not be regulating heater temperature, the cycling thermostat on the blower should be doing this.
You may have a grounded element (the element has sagged or broken and is touching the case) in which case none of the Hi-limit Cut off thermostats can regulate the temperature. Often you can see this by inspecting the heater assembly.
It can be checked with a meter.
Unplug the unit and remove the wires from the heater. Measure the heater should be around 10 ohms. Then measure from each connector to the case/frame both should be infinite ohms (open).
Another possibility is a restriction or leak in the air flow inside the unit.
The dryer is actually sucking air over the heating coils, through the drum and then pushing the air out the exhaust. If the lint filter is coated with fabric softener residue this can reduce the air flow significantly causing the heater to run hot.
Also the operating/cycling Hi-limit Cut off thermostat is on the blower wheel so if the unit is sucking in air through a blown seal, it sees a cooler temperature at the blower and again causes the heater to run hot.
Type | Hi-limit Cut off Thermostat & Resettable Thermal Switch |
Product Name | KSD301 KSD302 KSD306 KSD314 electric motor Hi-limit Cut off Thermostat & Resettable Thermal Switch |
Rating Current | 5A-60A |
Rating Voltage | 250V |
Certificate | ROHS CQC CCC TUV VDE |
Reset Type | Automatic/Manual Reset |
Application | Small Home Appliance, etc. |
Condition | Normal Open/Close, Manual / automatic reset |
Material | Plastic, Ceramic/Metel Shell |
Packing | PE Bag, Carton |
Poseu -vos en contacte amb nosaltres