Termostat de tall d'alta limitació de recanvi & Interruptor tèrmic reiniciable

KSD301, KD302, KSD306, KD308 Termostat de tall de límit alt & Interruptor tèrmic reiniciable Quan el circuit funciona correctament, els contactes estan en estat tancat. Quan s'arriba a la temperatura nominal de funcionament, el bimetall es deforma per la calor i es trenca ràpidament, tallant el circuit. Després d'això, el dispositiu comença a refredar-se.

Hi-limit Cut off Thermostat & Interruptor tèrmic reiniciable Quan el circuit funciona correctament, els contactes estan en estat tancat. Quan s'arriba a la temperatura nominal de funcionament, el bimetall es deforma per la calor i es trenca ràpidament, tallant el circuit. Després d'això, el dispositiu comença a refredar-se. When it reaches the specified reset temperature, the bimetallic strip and spring strip snap back to their starting position, the contacts will close again, and the device will start working again.

Interruptor de seguretat de límit d'alta temperatura de reinici manual de muntatge múltiple L350 °f Per a escalfador

Interruptor de seguretat de límit d'alta temperatura de reinici manual de muntatge múltiple L350 °f Per a escalfador

215° Termostat de límit alt reiniciable

215° Termostat de límit alt reiniciable

Ceramic Hi Limit OVER HEAT & Hi-Amp Thermal Cutoff Switch 240F

Ceramic Hi Limit OVER HEAT & Hi-Amp Thermal Cutoff Switch 240F

Replacement Resettable Thermal Cutoff Switch process:

Multi-mount Manual Reset High Temp Limit Safety Switch L350°f For heater.
The fuse on the heater is a safety device. The hi-limit thermostat should control the temperature so that the fuse does not blow. Therefore if the fuse does blow the hi-limit thermostat is not regulating the temperature so it is assumed that it is toast. Note that the hi-limit thermostat is also just a safety device.

If the unit is running on the hi-limit thermostat, this indicates a problem as the hi-limit thermostat should not be regulating heater temperature, the cycling thermostat on the blower should be doing this.

You may have a grounded element (the element has sagged or broken and is touching the case) in which case none of the Hi-limit Cut off thermostats can regulate the temperature. Often you can see this by inspecting the heater assembly.
It can be checked with a meter.
Unplug the unit and remove the wires from the heater. Measure the heater should be around 10 ohms. Then measure from each connector to the case/frame both should be infinite ohms (obert).

Another possibility is a restriction or leak in the air flow inside the unit.
The dryer is actually sucking air over the heating coils, through the drum and then pushing the air out the exhaust. If the lint filter is coated with fabric softener residue this can reduce the air flow significantly causing the heater to run hot.

Also the operating/cycling Hi-limit Cut off thermostat is on the blower wheel so if the unit is sucking in air through a blown seal, it sees a cooler temperature at the blower and again causes the heater to run hot.

Lletra Hi-limit Cut off Thermostat & Interruptor tèrmic reiniciable
Nom del producte KSD301 KSD302 KSD306 KSD314 electric motor Hi-limit Cut off Thermostat & Interruptor tèrmic reiniciable
Valoració actual 5A-60A
Rating Voltage 250V
Certificate ROHS CQC CCC TUV VDE
Restableix el tipus Automatic/Manual Reset
Aplicació Small Home Appliance, etc.
Condition Normal Open/Close, Manual / reinici automàtic
Material Plàstic, Ceramic/Metel Shell
Packing PE Bag, Carton