Produkkategorieë
- Termiese lont 32
- Sekke van die oppervlakbevestiging 12
- termistor 36
- PCB Mount Fuse Holder 27
- Bedrading tuig 6
- Blade lonthouers 17
- termostaat 50
- Elektriese lont 24
- Motor temperatuur sensor 7
- Termiese stroombreker 22
- Sekeringskashouer 36
- Temperatuursensor 75
- Termiese skakelaar 68
- Motor lont 20
- Bout afsmeltings 8
Produk tags
Disc Self Hold Thermal CUT OUT & Resistor Combination
The KSD301 / KSD302 series self-hold thermal cut-outs have an internal heater to stop them from auto-resetting. This means they can be located remotely and reset by switching off the applied voltage. KSD series 1/2″ , 3/4”disc manual-reset thermal cutouts offer extra thermal protection where auto-resetting devices are not desirable.
KSD301 / KSD302 thermostat disc self hold thermal cut out is a safety device that prevents a heater from overheating or faulting:
How thermostat disc self hold thermal cut out works?
When the temperature reaches a predetermined level, the thermostat opens, and the contacts remain open. The only way to reset the device is to remove power from the circuit.
thermostat disc self hold thermal cut out Benefits:
A self hold thermal cut out offers extra safety compared to an automatic reset device, and it works similarly to a manual reset device without the need for a push button.
Types of self hold thermal cut outs
Some types of self hold thermal cut outs include:
KSD301 / KSD302: A combination of a thermostat and a resistor, where the resistor is located below the thermostat’s contact arm.
KSD301 / KSD302 EAW SO: Similar to an auto-reset type, but with an internal heating resistor that prevents the bimetal disc from auto-resetting.
KSD302-T: A 1/2” disc PTC thermal cut-out that features easy mounting, rapid heat transmission, high durability, and high precision.
FEATURES
Recognized UL component, tested to UL standard 873
Available with surface, air sensing, well or cavity type mountings
High switching current 25~60 AMP/240 volts
Reliable temperature performance over the life of the device
Ultimate safety device in critical applications
Also available for 115VAC, 24VAC/DC, 48VAC/DC, applications
Various mounting configurations along with different terminations available
CODE | OPEN TEMP | RESET TEMP | CODE | OPEN TEMP | RESET TEMP | |
45 | 45±5°C | ≥33°C | 140 | 140±5°C | 100±15°C | |
50 | 50±5°C | ≥35°C | 145 | 145±5°C | 100±15°C | |
55 | 55±5°C | 42±6°C | 150 | 150±5°C | 105±15°C | |
60 | 60±5°C | 45±8°C | 155 | 155±5°C | 110±15°C | |
65 | 65±5°C | 48±10°C | 160 | 160±5°C | 115±15°C | |
70 | 70±5°C | 50±12°C | 165 | 165±5°C | 120±15°C | |
75 | 75±5°C | 53±14°C | 170 | 170±3°C | 155±5°C | |
80 | 80±5°C | 55±15°C | 175 | 175±5°C | 130±15°C | |
85 | 85±5°C | 60±15°C | 180 | 180±5°C | 135±15°C | |
90 | 90±5°C | 65±15°C | 185 | 185±5°C | 140±15°C | |
95 | 95±5°C | 70±15°C | 190 | 190±5°C | 145±15°C | |
100 | 100±5°C | 70±15°C | 195 | 195±5°C | 150±15°C | |
105 | 105±5°C | 75±15°C | 200 | 200±5°C | 155±15°C | |
110 | 110±5°C | 75±15°C | 205 | 205±5°C | 160±15°C | |
115 | 115±5°C | 80±15°C | 210 | 210±5°C | 165±15°C | |
120 | 120±5°C | 85±15°C | 215 | 215±5°C | 170±15°C | |
125 | 125±5°C | 85±15°C | 220 | 220±5°C | 175±15°C | |
130 | 130±5°C | 90±15°C | 225 | 225±5°C | 180±15°C | |
135 | 135±5°C | 95±15°C | 230 | 230±5°C | 185±15°C |