Vervanging Hi-Limit Cut Afgesnyde termostaat & Herstelbare termiese skakelaar

KSD301, KD302, KSD306, KD308 Hi-Limit Cut AFF-termostaat & Hervestigbare termiese skakelaar wanneer die kring behoorlik werk, Die kontakte is in 'n geslote toestand. Wanneer die gegradeerde bedryfstemperatuur bereik word, Die bimetaal word deur hitte vervorm en breek vinnig, Sny die stroombaan af. Daarna, Die toestel begin afkoel.

Hi-limit Cut off Thermostat & Hervestigbare termiese skakelaar wanneer die kring behoorlik werk, Die kontakte is in 'n geslote toestand. Wanneer die gegradeerde bedryfstemperatuur bereik word, Die bimetaal word deur hitte vervorm en breek vinnig, Sny die stroombaan af. Daarna, Die toestel begin afkoel. When it reaches the specified reset temperature, the bimetallic strip and spring strip snap back to their starting position, the contacts will close again, and the device will start working again.

Multi-montering Handleiding Reset Hoë temp Limiet Veiligheidskakelaar L350 ° F vir verwarmer

Multi-montering Handleiding Reset Hoë temp Limiet Veiligheidskakelaar L350 ° F vir verwarmer

215° Herstelbare hoë limiettermostaat

215° Herstelbare hoë limiettermostaat

Ceramic Hi Limit OVER HEAT & Hi-Amp Thermal Cutoff Switch 240F

Ceramic Hi Limit OVER HEAT & Hi-Amp Thermal Cutoff Switch 240F

Replacement Resettable Thermal Cutoff Switch process:

Multi-mount Manual Reset High Temp Limit Safety Switch L350°f For heater.
The fuse on the heater is a safety device. The hi-limit thermostat should control the temperature so that the fuse does not blow. Therefore if the fuse does blow the hi-limit thermostat is not regulating the temperature so it is assumed that it is toast. Note that the hi-limit thermostat is also just a safety device.

If the unit is running on the hi-limit thermostat, this indicates a problem as the hi-limit thermostat should not be regulating heater temperature, the cycling thermostat on the blower should be doing this.

You may have a grounded element (the element has sagged or broken and is touching the case) in which case none of the Hi-limit Cut off thermostats can regulate the temperature. Often you can see this by inspecting the heater assembly.
It can be checked with a meter.
Unplug the unit and remove the wires from the heater. Measure the heater should be around 10 ohms. Then measure from each connector to the case/frame both should be infinite ohms (open).

Another possibility is a restriction or leak in the air flow inside the unit.
The dryer is actually sucking air over the heating coils, through the drum and then pushing the air out the exhaust. If the lint filter is coated with fabric softener residue this can reduce the air flow significantly causing the heater to run hot.

Also the operating/cycling Hi-limit Cut off thermostat is on the blower wheel so if the unit is sucking in air through a blown seal, it sees a cooler temperature at the blower and again causes the heater to run hot.

Type Hi-limit Cut off Thermostat & Herstelbare termiese skakelaar
Produksnaam KSD301 KSD302 KSD306 KSD314 electric motor Hi-limit Cut off Thermostat & Herstelbare termiese skakelaar
Rating Current 5A-60A
Rating Voltage 250V
Certificate ROHS CQC CCC TUV VDE
Reset Type Automatic/Manual Reset
Application Small Home Appliance, ens.
Condition Normal Open/Close, Manual / Outomatiese herstel
Materiaal Plasties, Ceramic/Metel Shell
Packing PE Bag, Carton

Kontak ons

Wag vir u e -pos, Ons sal u binne antwoord 12 ure met waardevolle inligting wat u benodig.

Verwante produkte

Versoek 'n kwotasie

Vul ons aanhalingsversoekvorm in en ons sal so gou as moontlik op u boodskap antwoord!